Filtration Engineering & Consultant: Sales Office  :  9A, Gurudwara Road, opposite Metro Piller No. 816, (Near Dwarka Metro Station, New Delhi-43 (INDIA) Correspondence Address: : Plot No.35, Extn.  K-1, Street No.1, , Gurudwara Road, Mohan Garden, Uttam Nagar, New Delhi-59 Tel: +91-11 -25371015,  Contact Mr.T.P. Saxena Mo. 09811478874 9212912990, Tele F ax 011-25371015 E-mail: inquiry_fec@yahoo.com, info@fecproduct.com  House of  Testing Machine: www.fecproduct.com

Our Product Range

   Automobile, Paint & Plating
   Textile Garment, Fabric & Yarn
   Telecom Shelter & Sandwitch    Panel
   Filter & Filtration Media
   Plastic & Rubber
   Paper & Packaging
   Engineering & Medical College
   Pharmacentical & Hospital
   Metal & Sheet
   General Laboratory and R & D    Equipments
   SPM (Special Purpose Machine)
 
Calibration Services
Repairing
Spare Parts
Consumable Items
AMC of Equipments
 

   Oxygen Index Apparatus:

 
Oxygen index is defined as minimum concentration of oxygen, expressed as volume percent, in a mixture of oxygen and nitrogen that will just support flaming combustion of plastic materials under equilibrium condition of candle like burning. The equilibrium is established by the relation between the heat lost to the surroundings as measured by either time of burning or length of specimen burned. This point is approached from both sides of the critical oxygen concentration in order to establish the oxygen index.

TECHNICAL DATA

Dimensions of test column

75 mm inside diameter x 450 mm long

Rota meters

0.625 to 6.25 liter/minute for oxygen
1.05 to 10.5 liter/minute for nitrogen

Temperature indicator

Up to 199°C x 1°C

Timer

 Timer Up to 999 seconds x 1 second

The FEC Oxygen Index Apparatus consists of a test column made of borosilicate glass supported on a brass base. The mixture of nitrogen and oxygen is released from the bottom of tube, which is filled with glass beads for mixing and evenly distributing the gas mixture. A specimen holder is provided to hold the specimen vertically in the center of the test column with its lower end more than 100 mm above the top of glass beads.

The specimen holder is supported in a glass tube fixed at the center of the test column and can be taken out and inserted from the column. A thermocouple probe is also fitted in the test column above the surface of the beads to measure the temperature of the gases inside the column, which is indicated on a digital temperature indicator. A tube with suitable orifice for pilot flame is provided for igniting the specimen by inserting it from the top of the test column.