Digital Pore Determination Test Rig for filtration Media: |
| |
 |
| |
We are introduce our new and Improved product Digital filtration media pore determination test rig .This Equipment is very useful for filter Industry and filtration Media for check the Air Resistance ,Air permeability, Max Pore, Mean Pore, and micron rating of the filtration media
If would be appreciated that pore size and air permeability are very important characteristics for filtration media.
This Test rig made from BS : 6410 -1991, AARR Test method, Binzor Method, Graphical method also.
|
FEATURES:
- Direct digital reading on screen like Air Resistance, Airpermeability, Max Pore and Mean Pore
- Computer Attachment also available optional attachment
- There is no required for calculation
- This equipment made according to Binzer Method or AA RR Test method & BS : 6410 : 1991
- This equipment five in one.
- This equipment is designed as very easy to use and operate
- Included complete operating How to operate manual
- Reputed Base filter paper , Filter manufacturer and filter impregnated filter paper use this method
|
| |
| # THIS EQUIPMENT SUPPLIED WITH / WITHOUT COMPRESSORE WHICH IS OPTIONAL EXTRA. |
| |
| Specification: |
| |
| Operating inlet pressure |
: 1.5 Kg/Cm2 |
| Light |
: Light arrangement for Digital Model |
| No. of flow meters |
: 2 Nose |
| Range |
: 0.3 – 3.0 LPM |
| |
: 3 -30 LPM |
| Least count |
: 1 LPM for 30 LPM Flow meter |
| Digital manometer |
: LED Red bright display |
| |
: for mm WG |
| |
: Least count 1 mm |
| Sample clamping |
: manual tight very easy Or Pneumatic as per requirement |
| Air resistance at 24 LPM |
: 0 – 500 mmWG |
| Air porosity at 20 mm WG |
: 6 – 500 L/S/m2 |
| Pore size |
: 5 – 250 micron |
| Structure |
: Structure made from G.I Duly Epoxy paint and upper platform made from S.S |
- Calibrated Flow meters for accurate the desired flow
- Direct digital readout of Air Resistance, Air permeability, Max Pore size and Mean pore size for digital model
|
| |
|
| Pore determination Test rig (Analouge model) |
| Table top Model without compressor |
- Air resistance
- Air porosity
- Max Pore
- Mean Pore
- Micron rating on calculation
|
| Analouge Model : |
| |
|
|
| |
|
| Specification for analogue model Model : |
| |
|
| Operating inlet pressure |
: 1.5 Kg/Cm2 |
| Model |
: Table top model |
| No. of flow meters |
: 2 Nose |
| Range |
: 0.3 – 3.0 LPM
: 3 -30 LPM |
| Least count |
: 1 LPM for 30 LPM Flow meter |
| Manometer |
: U tube water manometer high quality
: for mm WG
: Least count 1 mm |
| Sample clamping |
: manual tight very easy |
| Air resistance at 24 LPM |
: 0 – 500 mmWG |
| Air porosity at 20 mm WG |
: 6 – 500 L/S/m2 |
| Pore size |
: 5 – 250 micron |
| Structure |
: Structure made from G.I Duly Epoxy paint and upper platform made from S.S |
| |
| Calibrated Flow meters for accurate the desired flow |
| |
|
| |
|
|
|
|
|